Document toolboxDocument toolbox

IDoc Inbound

IDoc Inbound is a test that will inject the message to the SAP backend. It can also perform validation of the database entries created by the message processing in the backend ABAP based system once the IDoc was posted successfully.

Top of the screen with Automation Object (AO) ID, description and test type.

 

Basic Information

 

Parameter name

Description

Example

IDoc Type

IDoc Message Type, Basic Type and Extension. All Separated by a “.”.

ORDERS.ORDERS05

Test Case Creation

Parameter name

Description

Example

Child Test Case Automation Object

Automation Object(s) used to link and create child test cases. This parameter allows for automatic creation of linked outbound test cases during save.

Following Automation Object types can be used as child:

5 PI E2E Outbound
7 IDoc Outbound
13 SAP CPI E2E Outbound

 

Backend Systems

Parameter name

Description

Example

Backend system line for current doc.

This parameter points out the system where the reference backend document is stored. The value should be a system line described in the landscape configuration.

Note:

If Backend system line for the current doc. has the same value as the Backend system line for the reference doc. (for instance, both are S4/HANA) then the RFC connection between the systems will be maintained both in:

a) the original environment of the reference document (for instance, production system)

b) the environment where the current test case execution takes place (for instance, development system) 

If Backend system line for the current doc. is different than the Backend system line for the reference doc. then, the RFC connection will be maintained only in the environment of the current execution (for instance, development system), but for both system lines (like ECC and S4HANA) 

ECC

SAP_ERP

 

Backend system line for reference doc.

This parameter points out the system line where Int4 Suite should create test documents during test case execution. In most cases, reference documents and documents created during current test execution are stored in the same system line. However, suppose Int4 Suite is used in a migration scenario (for example, migration from ECC to S4/HANA). In that case, the documents might be created in the new system and then compared with the references from the old system.

The value should be a system line described in the landscape configuration.

Note:

If Backend system line for the current doc. has the same value as the Backend system line for the reference doc. (for instance, both are S4/HANA) then the RFC connection between the systems will be maintained both in:

a) the original environment of the reference document (for instance, production system)

b) the environment where the current test case execution takes place (for instance, development system) 

If Backend system line for the current doc. is different than the Backend system line for the reference doc. then, the RFC connection will be maintained only in the environment of the current execution (for instance, development system), but for both system lines (like ECC and S4HANA) 

S4HANA

 

Database Validations

Parameter name

Description

Example

Database validation ruleset

Reference database validation ruleset object name.

Database validation ruleset specify how related backend validation should be performed. Specify tables, fields and join conditions for the backend validation.

Buttons allow navigation to the chosen database validation ruleset and creation of a new database validation ruleset
DB Validation Rulesets

GENERIC_SO

Persist reference DB Data

When switched on, DB reference data will be fetched from backend system during test case creation. Otherwise, it will be fetched during test case execution.

Automation Objects | Database Validations

 

Variables

Variables are the container for values that can be used during testing. Each variable contains two values, the one that is calculated based on the reference message/document and the one that is calculated ad-hoc during test case execution.

Variables & Variable processing

Create button allows variable creation.

Parameter name

Description

Example

Name

Variable technical name

VARIABLE_1

Description

Free text for variable description

Variable One

Type

Type of variable processing

Read & Replace

Find message

Custom

Scope

Scope determines the processing of procedures that generate unique values like, e.g., GUID or NUM_RANGE.

  • Test Case Scope - variable is replaced with new values considering values from the currently processed test case. The variable value, which occurs multiple times in the test case payload, is replaced with the same new value. The variable value in different test cases from the currently processed test run is replaced with a new value for each test case.

  • Test Run - variable is replaced with new values considering values from the currently processed test run. The variable value in different test cases from the currently processed test run is replaced with the same new value.

Test Case

Test Run

IDoc Status Validations

IDOC Status Validation parameters are used to override default status handling rules for Inbound and Outbound IDOC test types.

Default status handling is based on system settings configured in tables STACUST & STALIGHT:

  1. Read Status Group (STATVA) from STACUST

  2. Read Status traffic light (STALIGHT) from STALIGHT

STALIGHT

Int4 Suite Test Result

STALIGHT

Int4 Suite Test Result

1 - Yellow

Waiting for IDOC to be processed.

If maximum number of attempts exceeded Test is marked as Failed

2 - Green

Test marked as Failed

3 - Red

Test marked as Passed

Individual statuses can be specified in Automation Object rules to override the above logic.

Parameter name

Description

Example

IDoc Status

IDoc Status

53

Rule

Describes behaviour of Int4 Suite for IDoc status

Success - Mark as Passed

Execution Settings

Parameter name

Description

Example

Debug Log

Int4 Suite will provide additional, more technical information in Test Execution Report during the running of the test cases if this parameter is set. Therefore, it is recommended to set this option initially and deactivate it when object definition is confirmed after executing the first test cases

 

Display wait popup before validation

Wait Flag indicating if Int4 Suite should stop test case execution after sending test case message to middleware. Int4 Suite will show the confirmation box, and the user will decide to continue. This setting can execute manual follow-up actions before running the next test case or checking the validations.

This setup works only with Execute via SAP GUI option of execution

 

Delay between execution and validation

Parameter name

Description

Example

For each test case

Delay (in seconds) between test case execution ( sending message) and checking the results.

10

Once per test run

Delay (in seconds) between test run execution ( sending messages) and checking the results.

60

Number Ranges

The number ranges allow generating new values for variables. Those values are used to substitute original document numbers or other values in reference messages.

The number range used to replace the source system document number should always be configured to not overwrite the original number. It means that documents generated by Int4 Suite should have their own subset of the original document number. Usually, it might be a subset of the upper limit of the original number range.

It is essential that automated testing with Int4 Suite consume numbers that the source system will generate during manual testing. Additionally, if testing environment data is refreshed from the production system, more documents would be created in the testing environment. If the Int4 Suite number were configured in the same range, it would start creating duplicates.

For example, the original number range for document numbers from the source system is 560000 - 590000. It would be wise to set the Int4 Suite number range from 590000 to 600000. However, suppose the SAP backend system uses an external number range. It is essential to stay in the original range. In that case, the Int4 Suite number range may be set as 585000-590000, which gives space for 5000 testing documents. Using range from upper interval reduces the risk that the number will be overwritten.

Additionally, the good practice is to use prefixes or suffixes that will quickly separate source system documents and the ones created by Int4 Suite. It should always be used when there is no document number validation by the SAP backend.

Each Object Definition can contain an unlimited number of number ranges. This way, each variable declared in an object can use its specific number range.

 

Parameter name

Description

Example

Number range

Provide a name for the number range. This name would be passed as a parameter in variable processing for actions that will generate values from it.

NUM_RAN

Prefix

The alphanumeric characters to be appended at the beginning of the document number to separate original documents from source systems and the one created during Int4 Suite testing (optional).

INT4_

Low value

The first number of our range.

1

High value

The last number of our range.

999999

Current value

When the number range is used during testing, it would increment per each use.

23

Suffix

The alphanumeric characters to be appended at the end of the document number to separate original documents from source systems and the one created during Int4 Suite testing (optional).

_TEST

Add zeros

If this box is checked, zeros will be automatically appended to the beginning of the document number, such as 000500.

 

Incr. per Test Run

If this indicator is selected, the number range is incrementing once per test run. If multiple test cases with the same Automation Object exist in the test run, they will receive the same value.

 

Do not fail TC if DB reference not found

This flag determines if in the situation when DB validation for reference messages have not been found whether it should be treated as Error or Successful message.

Checked or 'X' - if reference document is not found test case will not be failed

Unchecked or '' - if reference document is not found test case will be failed (default setting)

Show XML in the original order (unsorted)

This flag determines if the lines of the file in the XML Comparison Report should be displayed in the original order or should be sorted alphabetically for a specific nodes.

Checked or 'X' - payload will not be sorted on the report

Unchecked or '' - payload will be sorted alphabetically (default value)

© 2017 - 2022 Int4 AG All rights reserved