How to test iFlow with AMPQ Adapter on SAP CPI

When AMPQ Adapter is used, there is no possibility to locate test message using Application ID or Correlation ID. Test message needs to be identified using payload check. To locate the message with correct payload Int4 Suite is using Variables. Variable needs to contain configuration that will generate new value and will use this new value to locate the correct test message.

In above example three mandatory steps are configured:

a) Read - selecting field that will contain new value in a input message

b) Replace - define how new value will be generated. It can be any of available engines that generates unique values, for example Number Range, Random Value, GUID, etc.

c) Find - define output field that should be used to locate test message

© 2017 - 2022 Int4 AG All rights reserved